Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui440V
Voltage typeAC
Current limiting class3
Built-in depth70.5mm
Frequency50 - 60Hz
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Suitable for flush-mounted installationNo
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Width in number of modular spacings3
Number of protected poles3
Concurrently switching neutral conductorNo
Rated voltage400V
Rated current40A
Release characteristicB
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-B40/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

440V

Voltage type

AC

Current limiting class

3

Built-in depth

70.5mm

Frequency

50 .. 60Hz

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Suitable for flush-mounted installation

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Width in number of modular spacings

3

Number of protected poles

3

Concurrently switching neutral conductor

Rated voltage

400V

Rated current

40A

Release characteristic

B

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

From same serie

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.