Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Built-in depth70.5mm
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Power loss2.3W
Additional equipment possibleYes
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of protected poles1
Rated current16A
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Over voltage category3
Ambient temperature during operating-25 - 75°C
Explosion-proofNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B16/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Power loss

2.3W

Additional equipment possible

Width in number of modular spacings

1

Concurrently switching neutral conductor

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of protected poles

1

Rated current

16A

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Related products