Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current40A
Rated voltage230V
Built-in depth70.5mm
Voltage typeAC
Over voltage category3
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Pollution degree2
Number of poles (total)1
Width in number of modular spacings1
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Release characteristicB
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA

Related products


Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL6-B40/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

40A

Rated voltage

230V

Built-in depth

70.5mm

Voltage type

AC

Over voltage category

3

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Pollution degree

2

Number of poles (total)

1

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Release characteristic

B

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

From same serie

Related products

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.