  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth69.5mm
Voltage typeAC
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Over voltage category3
Surge current capacity0.25kA
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated current13A
Current limiting class3
Rated impulse withstand voltage Uimp4kV
Pollution degree2
Anti-nuisance tripping versionNo
Rated voltage230V
Frequency50 Hz
Connectable conductor cross section multi-wired1 - 25mm²
With interlocking deviceNo
Release characteristicB
Connectable conductor cross section solid-core1 - 25mm²
Rated insulation voltage Ui440V
Number of poles (total)2
Number of protected poles1
Rated short-circuit breaking capacity according to IEC 60947-20kA
Leakage current typeA
Rated fault current0.03A
Ambient temperature during operating-25 - 40°C
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL7-13/1N/B/003-A

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

69.5mm

Voltage type

AC

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Over voltage category

3

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated current

13A

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Pollution degree

2

Anti-nuisance tripping version

Rated voltage

230V

Frequency

50 Hz

Connectable conductor cross section multi-wired

1 .. 25mm²

With interlocking device

Release characteristic

B

Connectable conductor cross section solid-core

1 .. 25mm²

Rated insulation voltage Ui

440V

Number of poles (total)

2

Number of protected poles

1

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Leakage current type

A

Rated fault current

0.03A

Ambient temperature during operating

-25 .. 40°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to EN 61009

10kA