Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth69.5mm
Voltage typeAC
Release characteristicB
Rated voltage230V
Current limiting class3
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Rated insulation voltage Ui440V
Width in number of modular spacings2
Frequency50 Hz
Leakage current typeAC
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity according to IEC 60947-20kA
With interlocking deviceNo
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 40°C
Number of poles (total)2
Number of protected poles1
Rated current32A
Rated fault current0.03A
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Concurrently switching neutral conductorYes
Surge current capacity0.25kA

Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL6-32/1N/B/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

69.5mm

Voltage type

AC

Release characteristic

B

Rated voltage

230V

Current limiting class

3

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Frequency

50 Hz

Leakage current type

AC

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

With interlocking device

Suitable for flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

Number of poles (total)

2

Number of protected poles

1

Rated current

32A

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Concurrently switching neutral conductor

Surge current capacity

0.25kA

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.