Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui440V
Built-in depth69.5mm
Rated voltage230V
Over voltage category3
Connectable conductor cross section solid-core1 - 25mm²
Frequency50 Hz
Width in number of modular spacings2
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 40°C
Degree of protection (IP)IP20
With interlocking deviceNo
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Current limiting class3
Mounting methodDIN rail
Leakage current typeAC
Number of protected poles1
Rated fault current0.03A
Rated current16A
Surge current capacity0.25kA
Voltage typeAC
Number of poles (total)2
Disconnection characteristicUndelayed
Release characteristicC
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA

Recommended products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL6-16/1N/C/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

440V

Built-in depth

69.5mm

Rated voltage

230V

Over voltage category

3

Connectable conductor cross section solid-core

1 .. 25mm²

Frequency

50 Hz

Width in number of modular spacings

2

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Suitable for flush-mounted installation

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

With interlocking device

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Current limiting class

3

Mounting method

DIN rail

Leakage current type

AC

Number of protected poles

1

Rated fault current

0.03A

Rated current

16A

Surge current capacity

0.25kA

Voltage type

AC

Number of poles (total)

2

Disconnection characteristic

Undelayed

Release characteristic

C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

From same serie

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.