Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity according to IEC 60947-20kA
Voltage typeAC
Rated fault current0.03A
Number of protected poles1
Degree of protection (IP)IP20
Width in number of modular spacings2
Frequency50 Hz
Rated current20A
With interlocking deviceNo
Surge current capacity0.25kA
Rated voltage230V
Connectable conductor cross section multi-wired1 - 25mm²
Current limiting class3
Leakage current typeAC
Release characteristicC
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 40°C
Built-in depth69.5mm
Over voltage category3
Concurrently switching neutral conductorYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL6-20/1N/C/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Voltage type

AC

Rated fault current

0.03A

Number of protected poles

1

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Frequency

50 Hz

Rated current

20A

With interlocking device

Surge current capacity

0.25kA

Rated voltage

230V

Connectable conductor cross section multi-wired

1 .. 25mm²

Current limiting class

3

Leakage current type

AC

Release characteristic

C

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Built-in depth

69.5mm

Over voltage category

3

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Number of poles (total)

2