Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current25A
Rated voltage230V
Leakage current typeAC
Rated insulation voltage Ui440V
Surge current capacity0.25kA
Current limiting class3
Frequency50 Hz
Rated fault current0.03A
Pollution degree2
Release characteristicC
Number of protected poles1
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-20kA
Degree of protection (IP)IP20
Over voltage category3
Built-in depth69.5mm
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 40°C
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 610096kA
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PFL6-25/1N/C/003

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

25A

Rated voltage

230V

Leakage current type

AC

Rated insulation voltage Ui

440V

Surge current capacity

0.25kA

Current limiting class

3

Frequency

50 Hz

Rated fault current

0.03A

Pollution degree

2

Release characteristic

C

Number of protected poles

1

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

0kA

Degree of protection (IP)

IP20

Over voltage category

3

Built-in depth

69.5mm

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Suitable for flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.