Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Frequency50 - 60Hz
Rated voltage230V
Rated current13A
Built-in depth70.5mm
Voltage typeAC
Degree of protection (IP)IP20
Width in number of modular spacings1
Current limiting class3
Over voltage category3
Number of protected poles1
Pollution degree2
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-C13/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Frequency

50 .. 60Hz

Rated voltage

230V

Rated current

13A

Built-in depth

70.5mm

Voltage type

AC

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Current limiting class

3

Over voltage category

3

Number of protected poles

1

Pollution degree

2

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA