Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicC
Number of protected poles2
Pollution degree2
Rated voltage400V
Current limiting class3
Rated current63A
Width in number of modular spacings2
Voltage typeAC
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Over voltage category3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Built-in depth70.5mm
Ambient temperature during operating-25 - 75°C
Number of poles (total)2
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-C63/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

C

Number of protected poles

2

Pollution degree

2

Rated voltage

400V

Current limiting class

3

Rated current

63A

Width in number of modular spacings

2

Voltage type

AC

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Over voltage category

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

Additional equipment possible

Built-in depth

70.5mm

Ambient temperature during operating

-25 .. 75°C

Number of poles (total)

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.