  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Voltage typeAC
Frequency50 - 60Hz
Rated current40A
Rated voltage400V
Rated insulation voltage Ui440V
Width in number of modular spacings2
Current limiting class3
Pollution degree2
Degree of protection (IP)IP20
Release characteristicD
Over voltage category3
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Number of protected poles2
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-D40/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

40A

Rated voltage

400V

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Release characteristic

D

Over voltage category

3

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Number of protected poles

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.