  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Release characteristicB
Built-in depth70.5mm
Rated insulation voltage Ui440V
Over voltage category3
Suitable for flush-mounted installationNo
Pollution degree2
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Connectable conductor cross section solid-core1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Number of protected poles3
Number of poles (total)3
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Width in number of modular spacings3
Rated voltage400V

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-B20/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Release characteristic

B

Built-in depth

70.5mm

Rated insulation voltage Ui

440V

Over voltage category

3

Suitable for flush-mounted installation

Pollution degree

2

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Additional equipment possible

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

3

Number of poles (total)

3

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Width in number of modular spacings

3

Rated voltage

400V