Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Width in number of modular spacings4
Built-in depth70.5mm
Voltage typeAC
Concurrently switching neutral conductorYes
Release characteristicC
Number of protected poles3
Pollution degree2
Rated voltage400V
Over voltage category3
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Rated current16A
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)4
Connectable conductor cross section solid-core1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL7-C16/3N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Width in number of modular spacings

4

Built-in depth

70.5mm

Voltage type

AC

Concurrently switching neutral conductor

Release characteristic

C

Number of protected poles

3

Pollution degree

2

Rated voltage

400V

Over voltage category

3

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Rated current

16A

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Additional equipment possible

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

From same serie