Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class3
Built-in depth75mm
Width in number of modular spacings6
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Release characteristicC
Degree of protection (IP)IP20
Over voltage category3
Voltage typeAC
Rated current63A
Pollution degree2
Number of protected poles3
Rated voltage400V
Connectable conductor cross section solid-core2.5 - 50mm²
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired2.5 - 50mm²
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

Item is no longer available for sale!

PLHT-C63/3N

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Current limiting class

3

Built-in depth

75mm

Width in number of modular spacings

6

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Release characteristic

C

Degree of protection (IP)

IP20

Over voltage category

3

Voltage type

AC

Rated current

63A

Pollution degree

2

Number of protected poles

3

Rated voltage

400V

Connectable conductor cross section solid-core

2.5 .. 50mm²

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Additional equipment possible

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Concurrently switching neutral conductor