Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Voltage typeAC
Rated current40A
Current limiting class3
Rated voltage230V
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Release characteristicD
Number of protected poles1
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Suitable for flush-mounted installationNo
Width in number of modular spacings1
Ambient temperature during operating-25 - 75°C
Number of poles (total)1
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV

Related products


Recommended products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

PL6-D40/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Voltage type

AC

Rated current

40A

Current limiting class

3

Rated voltage

230V

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Release characteristic

D

Number of protected poles

1

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Suitable for flush-mounted installation

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 75°C

Number of poles (total)

1

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Related products

Recommended products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.