Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Rated permanent current Iu250A
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Overload release current setting200 - 250A
Number of poles3
Adjustment range undelayed short-circuit release1500 - 2500A
Type of electrical connection of main circuitScrew connection
Motor drive optionalYes
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Type of control elementRocker lever
Complete device with protection unitYes
Rated voltage440 - 440V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB2-A250

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Rated permanent current Iu

250A

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Integrated earth fault protection

Overload release current setting

200 .. 250A

Number of poles

3

Adjustment range undelayed short-circuit release

1500 .. 2500A

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Type of control element

Rocker lever

Complete device with protection unit

Rated voltage

440 .. 440V

Related products