Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Overload release current setting125 - 160A
Rated permanent current Iu160A
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release960 - 1600A
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Type of control elementRocker lever
With integrated under voltage releaseNo
Motor drive integratedNo
Complete device with protection unitYes
Motor drive optionalYes
Degree of protection (IP)IP20
Position of connection for main current circuitFront side

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A160

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Overload release current setting

125 .. 160A

Rated permanent current Iu

160A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

960 .. 1600A

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of poles

3

Type of control element

Rocker lever

With integrated under voltage release

Motor drive integrated

Complete device with protection unit

Motor drive optional

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Related products