Technical specifications

Rated permanent current Iu630A
Rated voltage690 - 690V
Overload release current setting315 - 630A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release1260 - 5040A
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
With switched-off indicatorNo
Type of electrical connection of main circuitScrew connection
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Type of control elementRocker lever
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Motor drive optionalYes
Complete device with protection unitYes
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-AE630

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Rated voltage

690 .. 690V

Overload release current setting

315 .. 630A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

1260 .. 5040A

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

With switched-off indicator

Type of electrical connection of main circuit

Screw connection

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Type of control element

Rocker lever

With integrated under voltage release

Degree of protection (IP)

IP20

Motor drive optional

Complete device with protection unit

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Related products