  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting200 - 400A
Integrated earth fault protectionNo
Rated permanent current Iu400A
With integrated under voltage releaseNo
Type of electrical connection of main circuitScrew connection
Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release400 - 4000A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorNo
Number of poles3
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Adjustment range undelayed short-circuit release800 - 4400A
Degree of protection (IP)IP20
Motor drive integratedNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-VE400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

200 .. 400A

Integrated earth fault protection

Rated permanent current Iu

400A

With integrated under voltage release

Type of electrical connection of main circuit

Screw connection

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of poles

3

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Adjustment range undelayed short-circuit release

800 .. 4400A

Degree of protection (IP)

IP20

Motor drive integrated

Position of connection for main current circuit

Front side

Motor drive optional

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Related products