Technical specifications

Rated voltage690 - 690V
Overload release current setting500 - 1000A
Rated permanent current Iu1000A
Adjustment range short-term delayed short-circuit release0 - 0A
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Adjustment range undelayed short-circuit release2000 - 12000A
Complete device with protection unitYes
With switched-off indicatorNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of control elementRocker lever
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-AE1000

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Overload release current setting

500 .. 1000A

Rated permanent current Iu

1000A

Adjustment range short-term delayed short-circuit release

0 .. 0A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Adjustment range undelayed short-circuit release

2000 .. 12000A

Complete device with protection unit

With switched-off indicator

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of control element

Rocker lever

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20