Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuitScrew connection
Rated permanent current Iu800A
Overload release current setting400 - 800A
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Adjustment range undelayed short-circuit release1600 - 9600A
DIN rail (top hat rail) mounting optionalNo
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release800 - 8000A
Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz37kA
Motor drive integratedNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
Type of control elementRocker lever
Complete device with protection unitYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN4-VE800

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Type of electrical connection of main circuit

Screw connection

Rated permanent current Iu

800A

Overload release current setting

400 .. 800A

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Adjustment range undelayed short-circuit release

1600 .. 9600A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

37kA

Motor drive integrated

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Complete device with protection unit

Related products