Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage690 - 690V
Degree of protection (IP)IP20
Rated permanent current Iu50A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Type of control elementRocker lever
Type of electrical connection of main circuitFrame clamp
Overload release current setting40 - 50A
Motor drive integratedNo
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release6 - 10A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-4-A50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Degree of protection (IP)

IP20

Rated permanent current Iu

50A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

Type of control element

Rocker lever

Type of electrical connection of main circuit

Frame clamp

Overload release current setting

40 .. 50A

Motor drive integrated

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

6 .. 10A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Motor drive optional

Integrated earth fault protection

With switched-off indicator

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.