Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu80A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting63 - 80A
Rated voltage690 - 690V
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive optionalNo
With switched-off indicatorNo
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release6 - 10A
Number of poles4
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN1-4-A80

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

80A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

63 .. 80A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive optional

With switched-off indicator

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

6 .. 10A

Number of poles

4

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.