Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Overload release current setting63 - 80A
Rated permanent current Iu80A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Adjustment range undelayed short-circuit release6 - 10A
With integrated under voltage releaseNo
Motor drive optionalYes
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
Number of poles4

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-A80

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Overload release current setting

63 .. 80A

Rated permanent current Iu

80A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

With switched-off indicator

Adjustment range undelayed short-circuit release

6 .. 10A

With integrated under voltage release

Motor drive optional

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

Number of poles

4

Related products