Technical specifications

Rated permanent current Iu125A
Rated voltage690 - 690V
Overload release current setting100 - 125A
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release6 - 10A
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitScrew connection
With integrated under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Complete device with protection unitYes
Number of poles4
Motor drive integratedNo
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Type of control elementRocker lever
Device constructionBuilt-in device fixed built-in technique

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-A125

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

125A

Rated voltage

690 .. 690V

Overload release current setting

100 .. 125A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

6 .. 10A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Screw connection

With integrated under voltage release

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Complete device with protection unit

Number of poles

4

Motor drive integrated

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Device construction

Built-in device fixed built-in technique