  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device constructionBuilt-in device fixed built-in technique
Overload release current setting200 - 250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Rated permanent current Iu250A
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release6 - 10A
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
With integrated under voltage releaseNo
Rated voltage690 - 690V
With switched-off indicatorNo
Number of poles4
Complete device with protection unitYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementRocker lever
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-A250

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Device construction

Built-in device fixed built-in technique

Overload release current setting

200 .. 250A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Rated permanent current Iu

250A

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

6 .. 10A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

With integrated under voltage release

Rated voltage

690 .. 690V

With switched-off indicator

Number of poles

4

Complete device with protection unit

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Rocker lever

Motor drive optional

Related products