Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu250A
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release6 - 10A
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Rated voltage690 - 690V
Number of poles4
With switched-off indicatorNo
Overload release current setting200 - 250A
Degree of protection (IP)IP20
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-4-A250/160

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

250A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Position of connection for main current circuit

Front side

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Adjustment range undelayed short-circuit release

6 .. 10A

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Rated voltage

690 .. 690V

Number of poles

4

With switched-off indicator

Overload release current setting

200 .. 250A

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Related products