Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Rated permanent current Iu400A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Number of auxiliary contacts as normally open contact0
Overload release current setting200 - 400A
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release800 - 4400A
Number of auxiliary contacts as change-over contact0
Number of poles4
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of control elementRocker lever
Motor drive integratedNo
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Motor drive optionalYes
Complete device with protection unitYes
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
With integrated under voltage releaseNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH3-4-AE400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Rated permanent current Iu

400A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Number of auxiliary contacts as normally open contact

0

Overload release current setting

200 .. 400A

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

800 .. 4400A

Number of auxiliary contacts as change-over contact

0

Number of poles

4

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of control element

Rocker lever

Motor drive integrated

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Motor drive optional

Complete device with protection unit

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

With integrated under voltage release

Related products