Technical specifications

Overload release current setting125 - 250A
Adjustment range undelayed short-circuit release3000 - 3000A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release250 - 2500A
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Rated permanent current Iu250A
DIN rail (top hat rail) mounting optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Motor drive optionalYes
Rated voltage690 - 690V
Number of poles4
Degree of protection (IP)IP20
Complete device with protection unitYes
Integrated earth fault protectionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN2-4-VE250/160

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Overload release current setting

125 .. 250A

Adjustment range undelayed short-circuit release

3000 .. 3000A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

250 .. 2500A

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Rated permanent current Iu

250A

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Front side

Motor drive optional

Rated voltage

690 .. 690V

Number of poles

4

Degree of protection (IP)

IP20

Complete device with protection unit

Integrated earth fault protection

Related products