Technical specifications

Rated permanent current Iu630A
Type of electrical connection of main circuitScrew connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
Rated voltage690 - 690V
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Number of poles4
Adjustment range short-term delayed short-circuit release472 - 4410A
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
Adjustment range undelayed short-circuit release1260 - 5040A
Degree of protection (IP)IP20
Motor drive optionalYes
Motor drive integratedNo
Type of control elementRocker lever
Overload release current setting315 - 630A
Integrated earth fault protectionNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMN3-4-VE630/400

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

630A

Type of electrical connection of main circuit

Screw connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

Rated voltage

690 .. 690V

With switched-off indicator

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

With integrated under voltage release

Number of poles

4

Adjustment range short-term delayed short-circuit release

472 .. 4410A

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

Adjustment range undelayed short-circuit release

1260 .. 5040A

Degree of protection (IP)

IP20

Motor drive optional

Motor drive integrated

Type of control element

Rocker lever

Overload release current setting

315 .. 630A

Integrated earth fault protection