Technical specifications

Rated voltage690 - 690V
DIN rail (top hat rail) mounting optionalNo
Position of connection for main current circuitFront side
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Number of poles4
With integrated under voltage releaseNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
With switched-off indicatorNo
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Overload release current setting400 - 800A
Rated permanent current Iu800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release800 - 8000A
Adjustment range undelayed short-circuit release1600 - 9600A
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-4-VE800/500

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

With integrated under voltage release

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

With switched-off indicator

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Overload release current setting

400 .. 800A

Rated permanent current Iu

800A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Adjustment range undelayed short-circuit release

1600 .. 9600A

Degree of protection (IP)

IP20