Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range short-term delayed short-circuit release1000 - 10000A
Overload release current setting500 - 1000A
Device constructionBuilt-in device fixed built-in technique
Rated voltage690 - 690V
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release2000 - 12000A
DIN rail (top hat rail) mounting optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementRocker lever
Position of connection for main current circuitFront side
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Number of poles4
Motor drive integratedNo
Complete device with protection unitYes
With integrated under voltage releaseNo
Motor drive optionalYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH4-4-VE1000/630

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

Overload release current setting

500 .. 1000A

Device construction

Built-in device fixed built-in technique

Rated voltage

690 .. 690V

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

2000 .. 12000A

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Number of poles

4

Motor drive integrated

Complete device with protection unit

With integrated under voltage release

Motor drive optional

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.