Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as safety switchNo
Rated permanent current Iu125A
Rated permanent current at AC-23, 400 V0A
Max. rated operation voltage Ue AC690V
Rated operation power at AC-3, 400 V0kW
Version as reversing switchNo
Rated operation power at AC-23, 400 V55kW
Version as main switchYes
Number of switches1
Version as maintenance-/service switchYes
Rated permanent current at AC-21, 400 V0A
Number of auxiliary contacts as change-over contact0
Switching power at 400 V0kW
Version as emergency stop installationYes
Conditioned rated short-circuit current Iq0kA
Motor drive integratedNo
Voltage release optionalYes
Number of auxiliary contacts as normally open contact0
Device constructionBuilt-in device fixed built-in technique
Suitable for front mounting centreNo
Rated operating voltage690 - 690V
Suitable for front mounting 4-holeNo
Number of auxiliary contacts as normally closed contact0
Number of poles4
Suitable for floor mountingYes
Motor drive optionalNo
Rated short-time withstand current lcw2kA
Suitable for distribution board installationYes
With pre-assembled cablingNo
Degree of protection (IP), front sideIP20
InterlockableYes
Type of control elementRocker lever
Height145mm
Type of electrical connection of main circuitFrame clamp
Width120mm
Depth88mm
Colour control elementBlack
Suitable for intermediate mountingYes

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

N1-4-125

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Version as safety switch

Rated permanent current Iu

125A

Rated permanent current at AC-23, 400 V

0A

Max. rated operation voltage Ue AC

690V

Rated operation power at AC-3, 400 V

0kW

Version as reversing switch

Rated operation power at AC-23, 400 V

55kW

Version as main switch

Number of switches

1

Version as maintenance-/service switch

Rated permanent current at AC-21, 400 V

0A

Number of auxiliary contacts as change-over contact

0

Switching power at 400 V

0kW

Version as emergency stop installation

Conditioned rated short-circuit current Iq

0kA

Motor drive integrated

Voltage release optional

Number of auxiliary contacts as normally open contact

0

Device construction

Built-in device fixed built-in technique

Suitable for front mounting centre

Rated operating voltage

690 .. 690V

Suitable for front mounting 4-hole

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Suitable for floor mounting

Motor drive optional

Rated short-time withstand current lcw

2kA

Suitable for distribution board installation

With pre-assembled cabling

Degree of protection (IP), front side

IP20

Interlockable

Type of control element

Rocker lever

Height

145mm

Type of electrical connection of main circuit

Frame clamp

Width

120mm

Depth

88mm

Colour control element

Black

Suitable for intermediate mounting

Related products