Rated permanent current Iu160A
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release1280 - 1280A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Type of electrical connection of main circuitFrame clamp
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Device constructionBuilt-in device fixed built-in technique
Overload release current setting125 - 160A
Rated voltage440 - 440V
Number of poles4
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Complete device with protection unitYes
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Type of control elementRocker lever
With switched-off indicatorNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMB1-4-A160

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

160A

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

1280 .. 1280A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of electrical connection of main circuit

Frame clamp

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Device construction

Built-in device fixed built-in technique

Overload release current setting

125 .. 160A

Rated voltage

440 .. 440V

Number of poles

4

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Complete device with protection unit

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Type of control element

Rocker lever

With switched-off indicator

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0