Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage690 - 690V
Adjustment range short-term delayed short-circuit release0 - 0A
Rated permanent current Iu25A
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release350 - 350A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
With integrated under voltage releaseNo
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Number of poles3
Integrated earth fault protectionNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive integratedNo
Overload release current setting20 - 25A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A25

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated voltage

690 .. 690V

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated permanent current Iu

25A

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

350 .. 350A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

Motor drive optional

DIN rail (top hat rail) mounting optional

Number of poles

3

Integrated earth fault protection

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive integrated

Overload release current setting

20 .. 25A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.