Technical specifications

Rated permanent current Iu32A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting25 - 32A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release350 - 350A
Rated voltage690 - 690V
Type of electrical connection of main circuitScrew connection
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Number of poles3
With switched-off indicatorNo
Complete device with protection unitYes
Motor drive optionalYes
Motor drive integratedNo
Type of control elementRocker lever
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH2-A32

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

32A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

25 .. 32A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range undelayed short-circuit release

350 .. 350A

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Screw connection

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Number of poles

3

With switched-off indicator

Complete device with protection unit

Motor drive optional

Motor drive integrated

Type of control element

Rocker lever

Degree of protection (IP)

IP20