  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu32A
Overload release current setting25 - 32A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitFrame clamp
Adjustment range undelayed short-circuit release350 - 350A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
Type of control elementRocker lever
Motor drive optionalNo
Integrated earth fault protectionNo
Number of poles4
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH1-4-A32

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

32A

Overload release current setting

25 .. 32A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

DIN rail (top hat rail) mounting optional

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Frame clamp

Adjustment range undelayed short-circuit release

350 .. 350A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Complete device with protection unit

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Motor drive optional

Integrated earth fault protection

Number of poles

4

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Degree of protection (IP)

IP20