Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release8 - 10A
Rated permanent current Iu40A
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Overload release current setting32 - 40A
Rated voltage690 - 690V
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of poles4
Motor drive integratedNo
DIN rail (top hat rail) mounting optionalYes
Type of electrical connection of main circuitFrame clamp
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive optionalNo
Position of connection for main current circuitFront side
Type of control elementRocker lever

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH1-4-A40

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

8 .. 10A

Rated permanent current Iu

40A

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Overload release current setting

32 .. 40A

Rated voltage

690 .. 690V

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Motor drive integrated

DIN rail (top hat rail) mounting optional

Type of electrical connection of main circuit

Frame clamp

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive optional

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Related products