Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu50A
Rated voltage690 - 690V
Overload release current setting40 - 50A
Adjustment range undelayed short-circuit release6 - 10A
Adjustment range short-term delayed short-circuit release0 - 0A
Integrated earth fault protectionNo
Type of electrical connection of main circuitFrame clamp
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Type of control elementRocker lever
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalNo
Degree of protection (IP)IP20

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

NZMH1-4-A50

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

50A

Rated voltage

690 .. 690V

Overload release current setting

40 .. 50A

Adjustment range undelayed short-circuit release

6 .. 10A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Integrated earth fault protection

Type of electrical connection of main circuit

Frame clamp

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

With integrated under voltage release

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

Related products