Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- EATON
Technical specifications
Suitable as guard
Yes
Suitable as 2-point controller
Yes
Max. operating pressure
16000hPa
Initial setting
0 - 0hPa
Engaging pressure
0 - 13.1bar
Pressure-switching differential
0bar
Suitable as limiter
No
Bursting pressure
90bar
Max. test pressure
32bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
End setting
0 - 0hPa
End value measuring range pressure
0Pa
Rated voltage Ue at AC 50 Hz
0 - 400V
Initial value measuring range pressure
0Pa
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-1, 400 V
0A
Rated operation current Ie at AC-3, 400 V
11.5A
Number of auxiliary contacts as normally open contact
0
Rated voltage Ue at AC 60 Hz
0 - 400V
Thread size
1/2 inch
Type of electric connection
Screw connection
Switching capacity at AC-3, 240 V
0kA
Number of normally open contacts as main contact
0
Adjustable current range
0 - 0A
With manual on/off switch
No
Switch off pressure
0 - 16bar
Explosion-proof
No
With hand operation
No
Electronic version
No
Rated operation power at AC-3, 400 V
5.5kW
With display
No
Width
60mm
Height
111mm
Medium temperature
25 - 80°C
Rated voltage Ue at DC
0 - 250V
Number of normally closed contacts as main contact
3
Number of auxiliary contacts as change-over contact
0
Depth
96mm
Diameter
0mm
Degree of protection (IP)
IP65
Degree of protection (NEMA)
Other
Related products
From same serie
MCSN16

Details
- Low-voltage industrial components
- Pressure switch
- 1 KOM
- EATON
Technical specifications
Suitable as guard
Suitable as 2-point controller
Max. operating pressure
16000hPa
Initial setting
0 .. 0hPa
Engaging pressure
0 .. 13.1bar
Pressure-switching differential
0bar
Suitable as limiter
Bursting pressure
90bar
Max. test pressure
32bar
Connection
Internal thread cylindrical BSPP-G (ISO 228-1)
End setting
0 .. 0hPa
End value measuring range pressure
0Pa
Rated voltage Ue at AC 50 Hz
0 .. 400V
Initial value measuring range pressure
0Pa
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie at AC-1, 400 V
0A
Rated operation current Ie at AC-3, 400 V
11.5A
Number of auxiliary contacts as normally open contact
0
Rated voltage Ue at AC 60 Hz
0 .. 400V
Thread size
1/2 inch
Type of electric connection
Screw connection
Switching capacity at AC-3, 240 V
0kA
Number of normally open contacts as main contact
0
Adjustable current range
0 .. 0A
With manual on/off switch
Switch off pressure
0 .. 16bar
Explosion-proof
With hand operation
Electronic version
Rated operation power at AC-3, 400 V
5.5kW
With display
Width
60mm
Height
111mm
Medium temperature
25 .. 80°C
Rated voltage Ue at DC
0 .. 250V
Number of normally closed contacts as main contact
3
Number of auxiliary contacts as change-over contact
0
Depth
96mm
Diameter
0mm
Degree of protection (IP)
IP65
Degree of protection (NEMA)
Other
From same serie
Related products
We use cookies to enhance your experience.