Aleta.hr

Details

  • Sensors
  • End switch
  • 1 KOM
  • EATON

Technical specifications

Explosion safety category for dustNone
Type of interface for safety communicationNone
Material housingPlastic
Construction type housingCuboid
With status indicationNo
Rated operation current Ie at AC-15, 230 V6A
Degree of protection (IP)IP66/IP67
Rated operation current Ie at DC-13, 230 V0.3A
Explosion safety category for gasNone
Type of electric connectionCable entry metrical
Suitable for safety functionsYes
Switching functionQuick-break switch
Coating housingOther
Number of safety auxiliary contacts1
Output electronicNo
Length of sensor33.5mm
Type of interfaceNone
Degree of protection (NEMA)Other
Rated operation current Ie at DC-13, 24 V3A
Diameter sensor0mm
Type of control elementRoller cam
Number of contacts as normally open contact1
Switching function latchingNo
Alignment of the control elementRoller cam straight
Rated operation current Ie at AC-15, 24 V6A
Number of contacts as normally closed contact1
Rated operation current Ie at AC-15, 125 V6A
Forced openingYes
Height of sensor61mm
Width sensor31mm
Ambient temperature during operating-25 - 70°C
Number of contacts as change-over contact0
Rated operation current Ie at DC-13, 125 V0.8A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

LS-11S/P

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Sensors
  • End switch
  • 1 KOM
  • EATON

Technical specifications

Explosion safety category for dust

None

Type of interface for safety communication

None

Material housing

Plastic

Construction type housing

Cuboid

With status indication

Rated operation current Ie at AC-15, 230 V

6A

Degree of protection (IP)

IP66/IP67

Rated operation current Ie at DC-13, 230 V

0.3A

Explosion safety category for gas

None

Type of electric connection

Cable entry metrical

Suitable for safety functions

Switching function

Quick-break switch

Coating housing

Other

Number of safety auxiliary contacts

1

Output electronic

Length of sensor

33.5mm

Type of interface

None

Degree of protection (NEMA)

Other

Rated operation current Ie at DC-13, 24 V

3A

Diameter sensor

0mm

Type of control element

Roller cam

Number of contacts as normally open contact

1

Switching function latching

Alignment of the control element

Roller cam straight

Rated operation current Ie at AC-15, 24 V

6A

Number of contacts as normally closed contact

1

Rated operation current Ie at AC-15, 125 V

6A

Forced opening

Height of sensor

61mm

Width sensor

31mm

Ambient temperature during operating

-25 .. 70°C

Number of contacts as change-over contact

0

Rated operation current Ie at DC-13, 125 V

0.8A