Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles1
Type of control elementDoor coupling rotary drive
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu32A
Motor drive optionalNo
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Device constructionBuilt-in device fixed built-in technique
Degree of protection (NEMA)12
Rated operation power at AC-3, 400 V11kW
Degree of protection (IP), front sideIP65
Suitable for floor mountingYes
Suitable for intermediate mountingYes
Suitable for distribution board installationNo
Conditioned rated short-circuit current Iq1kA
Max. rated operation voltage Ue AC690V
Rated operating voltage690 - 690V
Version as main switchYes
Suitable for front mounting 4-holeNo
Rated permanent current at AC-21, 400 V32A
Version as emergency stop installationNo
Voltage release optionalNo
InterlockableYes
Version as reversing switchNo
Switching power at 400 V15kW
Version as maintenance-/service switchYes
Number of switches1
Rated permanent current at AC-23, 400 V32A
Rated short-time withstand current lcw0.65kA
Colour control elementBlack
Rated operation power at AC-23, 400 V15kW
Suitable for front mounting centreNo
Version as safety switchNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T3-1-8200/V/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector
  • 1 KOM
  • EATON

Technical specifications

Number of poles

1

Type of control element

Door coupling rotary drive

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

32A

Motor drive optional

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Device construction

Built-in device fixed built-in technique

Degree of protection (NEMA)

12

Rated operation power at AC-3, 400 V

11kW

Degree of protection (IP), front side

IP65

Suitable for floor mounting

Suitable for intermediate mounting

Suitable for distribution board installation

Conditioned rated short-circuit current Iq

1kA

Max. rated operation voltage Ue AC

690V

Rated operating voltage

690 .. 690V

Version as main switch

Suitable for front mounting 4-hole

Rated permanent current at AC-21, 400 V

32A

Version as emergency stop installation

Voltage release optional

Interlockable

Version as reversing switch

Switching power at 400 V

15kW

Version as maintenance-/service switch

Number of switches

1

Rated permanent current at AC-23, 400 V

32A

Rated short-time withstand current lcw

0.65kA

Colour control element

Black

Rated operation power at AC-23, 400 V

15kW

Suitable for front mounting centre

Version as safety switch

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.