Technical specifications

Max. rated operation voltage Ue AC690V
Rated permanent current at AC-23, 400 V32A
Version as emergency stop installationNo
Rated operating voltage690 - 690V
Version as reversing switchNo
Rated permanent current at AC-21, 400 V32A
Switching power at 400 V15kW
Number of switches1
Number of auxiliary contacts as normally closed contact1
Version as maintenance-/service switchYes
Number of auxiliary contacts as normally open contact2
Rated permanent current Iu32A
Conditioned rated short-circuit current Iq1kA
Motor drive optionalNo
Number of auxiliary contacts as change-over contact0
Rated operation power at AC-23, 400 V15kW
Device constructionBuilt-in device fixed built-in technique
Type of control elementDoor coupling rotary drive
Version as safety switchNo
InterlockableYes
Suitable for front mounting 4-holeNo
Voltage release optionalNo
Type of electrical connection of main circuitScrew connection
With pre-assembled cablingNo
Rated short-time withstand current lcw0.65kA
Number of poles3
Degree of protection (IP), front sideIP65
Suitable for floor mountingNo
Motor drive integratedNo
Version as main switchYes
Rated operation power at AC-3, 400 V11kW
Suitable for front mounting centreYes
Suitable for intermediate mountingNo
Colour control elementBlack
Suitable for distribution board installationNo
Depth127mm
Height74mm
Width65mm
Degree of protection (NEMA)12

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T3-3-15683/EA/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Rated permanent current at AC-23, 400 V

32A

Version as emergency stop installation

Rated operating voltage

690 .. 690V

Version as reversing switch

Rated permanent current at AC-21, 400 V

32A

Switching power at 400 V

15kW

Number of switches

1

Number of auxiliary contacts as normally closed contact

1

Version as maintenance-/service switch

Number of auxiliary contacts as normally open contact

2

Rated permanent current Iu

32A

Conditioned rated short-circuit current Iq

1kA

Motor drive optional

Number of auxiliary contacts as change-over contact

0

Rated operation power at AC-23, 400 V

15kW

Device construction

Built-in device fixed built-in technique

Type of control element

Door coupling rotary drive

Version as safety switch

Interlockable

Suitable for front mounting 4-hole

Voltage release optional

Type of electrical connection of main circuit

Screw connection

With pre-assembled cabling

Rated short-time withstand current lcw

0.65kA

Number of poles

3

Degree of protection (IP), front side

IP65

Suitable for floor mounting

Motor drive integrated

Version as main switch

Rated operation power at AC-3, 400 V

11kW

Suitable for front mounting centre

Suitable for intermediate mounting

Colour control element

Black

Suitable for distribution board installation

Depth

127mm

Height

74mm

Width

65mm

Degree of protection (NEMA)

12