Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC500V
Rated permanent current at AC-23, 400 V6.6A
Rated operation power at AC-3, 400 V0kW
Version as reversing switchNo
Version as safety switchNo
Version as maintenance-/service switchNo
Rated permanent current at AC-21, 400 V0A
Version as main switchNo
Rated operation power at AC-23, 400 V3kW
Rated short-time withstand current lcw0kA
Number of switches1
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Switching power at 400 V0kW
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu10A
Version as emergency stop installationYes
Number of poles1
Rated operating voltage690 - 690V
Motor drive optionalNo
Motor drive integratedNo
Suitable for front mounting centreNo
Voltage release optionalNo
Suitable for distribution board installationNo
Number of auxiliary contacts as change-over contact0
Suitable for floor mountingNo
Suitable for front mounting 4-holeYes
Suitable for intermediate mountingNo
Conditioned rated short-circuit current Iq0kA
Height48mm
InterlockableYes
Degree of protection (NEMA)12
Type of electrical connection of main circuitScrew connection
Colour control elementRed
Depth77mm
With pre-assembled cablingNo
Width30mm
Degree of protection (IP), front sideIP65
Type of control elementDoor coupling rotary drive

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

TM-1-8290/E/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

500V

Rated permanent current at AC-23, 400 V

6.6A

Rated operation power at AC-3, 400 V

0kW

Version as reversing switch

Version as safety switch

Version as maintenance-/service switch

Rated permanent current at AC-21, 400 V

0A

Version as main switch

Rated operation power at AC-23, 400 V

3kW

Rated short-time withstand current lcw

0kA

Number of switches

1

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Switching power at 400 V

0kW

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

10A

Version as emergency stop installation

Number of poles

1

Rated operating voltage

690 .. 690V

Motor drive optional

Motor drive integrated

Suitable for front mounting centre

Voltage release optional

Suitable for distribution board installation

Number of auxiliary contacts as change-over contact

0

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for intermediate mounting

Conditioned rated short-circuit current Iq

0kA

Height

48mm

Interlockable

Degree of protection (NEMA)

12

Type of electrical connection of main circuit

Screw connection

Colour control element

Red

Depth

77mm

With pre-assembled cabling

Width

30mm

Degree of protection (IP), front side

IP65

Type of control element

Door coupling rotary drive

Related products