Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
No
Version as maintenance-/service switch
No
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
690V
Version as safety switch
No
Rated operation power at AC-3, 400 V
13kW
Rated operating voltage
690 - 690V
Rated permanent current Iu
32A
Number of switches
1
Rated operation power at AC-23, 400 V
15kW
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
32A
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Rated short-time withstand current lcw
0.64kA
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Suitable for front mounting 4-hole
Yes
Conditioned rated short-circuit current Iq
80kA
Suitable for floor mounting
No
Switching power at 400 V
15kW
Rated permanent current at AC-21, 400 V
32A
Suitable for distribution board installation
No
Type of electrical connection of main circuit
Screw connection
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP65
Suitable for front mounting centre
No
Degree of protection (NEMA)
12
Type of control element
Short thumb-grip
With pre-assembled cabling
No
Width
49mm
Height
73mm
Interlockable
No
Colour control element
Black
Depth
139mm
P1-32/E/SVA(A)

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as emergency stop installation
Max. rated operation voltage Ue AC
690V
Version as safety switch
Rated operation power at AC-3, 400 V
13kW
Rated operating voltage
690 .. 690V
Rated permanent current Iu
32A
Number of switches
1
Rated operation power at AC-23, 400 V
15kW
Version as reversing switch
Rated permanent current at AC-23, 400 V
32A
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Rated short-time withstand current lcw
0.64kA
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Suitable for front mounting 4-hole
Conditioned rated short-circuit current Iq
80kA
Suitable for floor mounting
Switching power at 400 V
15kW
Rated permanent current at AC-21, 400 V
32A
Suitable for distribution board installation
Type of electrical connection of main circuit
Screw connection
Suitable for intermediate mounting
Degree of protection (IP), front side
IP65
Suitable for front mounting centre
Degree of protection (NEMA)
12
Type of control element
Short thumb-grip
With pre-assembled cabling
Width
49mm
Height
73mm
Interlockable
Colour control element
Black
Depth
139mm
We use cookies to enhance your experience.