Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as main switch
No
Number of switches
1
Version as reversing switch
No
Rated short-time withstand current lcw
0.65kA
Version as maintenance-/service switch
No
Version as emergency stop installation
No
Rated permanent current at AC-21, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Rated permanent current Iu
32A
Rated operation power at AC-23, 400 V
15kW
Number of auxiliary contacts as normally closed contact
0
Rated operating voltage
690 - 690V
Version as safety switch
No
Motor drive optional
No
Number of auxiliary contacts as change-over contact
0
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
1kA
Number of poles
6
Device construction
Built-in device fixed built-in technique
Voltage release optional
No
Suitable for floor mounting
Yes
Suitable for front mounting centre
No
Number of auxiliary contacts as normally open contact
0
Suitable for distribution board installation
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
Yes
Width
61mm
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
Colour control element
Black
Degree of protection (IP), front side
IP65
Interlockable
No
Degree of protection (NEMA)
12
Motor drive integrated
No
Depth
144mm
With pre-assembled cabling
No
Height
54mm
From same serie
T3-3-8342/Z

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
32A
Version as main switch
Number of switches
1
Version as reversing switch
Rated short-time withstand current lcw
0.65kA
Version as maintenance-/service switch
Version as emergency stop installation
Rated permanent current at AC-21, 400 V
32A
Rated operation power at AC-3, 400 V
11kW
Rated permanent current Iu
32A
Rated operation power at AC-23, 400 V
15kW
Number of auxiliary contacts as normally closed contact
0
Rated operating voltage
690 .. 690V
Version as safety switch
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Switching power at 400 V
15kW
Conditioned rated short-circuit current Iq
1kA
Number of poles
6
Device construction
Built-in device fixed built-in technique
Voltage release optional
Suitable for floor mounting
Suitable for front mounting centre
Number of auxiliary contacts as normally open contact
0
Suitable for distribution board installation
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Width
61mm
Type of electrical connection of main circuit
Screw connection
Type of control element
Door coupling rotary drive
Colour control element
Black
Degree of protection (IP), front side
IP65
Interlockable
Degree of protection (NEMA)
12
Motor drive integrated
Depth
144mm
With pre-assembled cabling
Height
54mm
From same serie