Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact1
Conditioned rated short-circuit current Iq2kA
Rated permanent current Iu63A
Height88mm
Width88mm
Rated operating voltage690 - 690V
Depth221mm
Rated operation power at AC-3, 400 V22kW
Number of poles9
Degree of protection (IP), front sideIP65
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact2
InterlockableYes
Motor drive integratedNo
Number of switches1
Version as maintenance-/service switchYes
Type of control elementDoor coupling rotary drive
Version as emergency stop installationYes
Rated short-time withstand current lcw1.3kA
Version as safety switchNo
Suitable for front mounting 4-holeNo
Type of electrical connection of main circuitScrew connection
Suitable for floor mountingYes
Colour control elementRed
With pre-assembled cablingNo
Suitable for intermediate mountingYes
Rated operation power at AC-23, 400 V30kW
Suitable for distribution board installationNo
Switching power at 400 V30kW
Rated permanent current at AC-21, 400 V63A
Version as main switchYes
Suitable for front mounting centreNo
Voltage release optionalNo
Version as reversing switchNo
Rated permanent current at AC-23, 400 V63A
Degree of protection (NEMA)12
Motor drive optionalNo
Max. rated operation voltage Ue AC690V
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5B-6-15168/V/SVB

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

1

Conditioned rated short-circuit current Iq

2kA

Rated permanent current Iu

63A

Height

88mm

Width

88mm

Rated operating voltage

690 .. 690V

Depth

221mm

Rated operation power at AC-3, 400 V

22kW

Number of poles

9

Degree of protection (IP), front side

IP65

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

2

Interlockable

Motor drive integrated

Number of switches

1

Version as maintenance-/service switch

Type of control element

Door coupling rotary drive

Version as emergency stop installation

Rated short-time withstand current lcw

1.3kA

Version as safety switch

Suitable for front mounting 4-hole

Type of electrical connection of main circuit

Screw connection

Suitable for floor mounting

Colour control element

Red

With pre-assembled cabling

Suitable for intermediate mounting

Rated operation power at AC-23, 400 V

30kW

Suitable for distribution board installation

Switching power at 400 V

30kW

Rated permanent current at AC-21, 400 V

63A

Version as main switch

Suitable for front mounting centre

Voltage release optional

Version as reversing switch

Rated permanent current at AC-23, 400 V

63A

Degree of protection (NEMA)

12

Motor drive optional

Max. rated operation voltage Ue AC

690V

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.