Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC690V
Rated permanent current at AC-23, 400 V63A
Version as maintenance-/service switchYes
Number of switches1
Version as safety switchNo
Version as emergency stop installationYes
Rated operating voltage690 - 690V
Rated permanent current at AC-21, 400 V63A
Version as main switchYes
Rated permanent current Iu63A
Rated operation power at AC-23, 400 V30kW
Rated short-time withstand current lcw1.3kA
Rated operation power at AC-3, 400 V22kW
Switching power at 400 V30kW
Number of auxiliary contacts as change-over contact0
Conditioned rated short-circuit current Iq2kA
Number of poles2
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Suitable for floor mountingYes
Voltage release optionalNo
Motor drive integratedNo
Suitable for front mounting centreNo
Suitable for intermediate mountingYes
Suitable for distribution board installationNo
Suitable for front mounting 4-holeNo
Version as reversing switchNo
Motor drive optionalNo
Type of control elementDoor coupling rotary drive
Degree of protection (NEMA)12
InterlockableYes
Degree of protection (IP), front sideIP65
Depth138mm
Colour control elementRed
Type of electrical connection of main circuitScrew connection
Height88mm
With pre-assembled cablingNo
Width88mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5B-1-102/V/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Rated permanent current at AC-23, 400 V

63A

Version as maintenance-/service switch

Number of switches

1

Version as safety switch

Version as emergency stop installation

Rated operating voltage

690 .. 690V

Rated permanent current at AC-21, 400 V

63A

Version as main switch

Rated permanent current Iu

63A

Rated operation power at AC-23, 400 V

30kW

Rated short-time withstand current lcw

1.3kA

Rated operation power at AC-3, 400 V

22kW

Switching power at 400 V

30kW

Number of auxiliary contacts as change-over contact

0

Conditioned rated short-circuit current Iq

2kA

Number of poles

2

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Suitable for floor mounting

Voltage release optional

Motor drive integrated

Suitable for front mounting centre

Suitable for intermediate mounting

Suitable for distribution board installation

Suitable for front mounting 4-hole

Version as reversing switch

Motor drive optional

Type of control element

Door coupling rotary drive

Degree of protection (NEMA)

12

Interlockable

Degree of protection (IP), front side

IP65

Depth

138mm

Colour control element

Red

Type of electrical connection of main circuit

Screw connection

Height

88mm

With pre-assembled cabling

Width

88mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.