Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC690V
Rated permanent current at AC-23, 400 V100A
Version as main switchYes
Version as maintenance-/service switchYes
Version as reversing switchNo
Version as safety switchNo
Version as emergency stop installationNo
Rated operating voltage690 - 690V
Rated operation power at AC-3, 400 V30kW
Rated permanent current at AC-21, 400 V100A
Number of switches1
Rated permanent current Iu100A
Rated short-time withstand current lcw1.7kA
Rated operation power at AC-23, 400 V55kW
Switching power at 400 V55kW
Conditioned rated short-circuit current Iq2kA
Number of poles8
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Motor drive optionalNo
Voltage release optionalNo
Device constructionBuilt-in device fixed built-in technique
Suitable for floor mountingYes
Suitable for front mounting 4-holeNo
Suitable for front mounting centreNo
Suitable for distribution board installationNo
Suitable for intermediate mountingYes
Type of control elementDoor coupling rotary drive
Colour control elementBlack
InterlockableYes
Type of electrical connection of main circuitScrew connection
With pre-assembled cablingNo
Degree of protection (IP), front sideIP65
Width88mm
Degree of protection (NEMA)12
Depth188mm
Height88mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5-4-8344/V/SVB-SW

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Rated permanent current at AC-23, 400 V

100A

Version as main switch

Version as maintenance-/service switch

Version as reversing switch

Version as safety switch

Version as emergency stop installation

Rated operating voltage

690 .. 690V

Rated operation power at AC-3, 400 V

30kW

Rated permanent current at AC-21, 400 V

100A

Number of switches

1

Rated permanent current Iu

100A

Rated short-time withstand current lcw

1.7kA

Rated operation power at AC-23, 400 V

55kW

Switching power at 400 V

55kW

Conditioned rated short-circuit current Iq

2kA

Number of poles

8

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Motor drive optional

Voltage release optional

Device construction

Built-in device fixed built-in technique

Suitable for floor mounting

Suitable for front mounting 4-hole

Suitable for front mounting centre

Suitable for distribution board installation

Suitable for intermediate mounting

Type of control element

Door coupling rotary drive

Colour control element

Black

Interlockable

Type of electrical connection of main circuit

Screw connection

With pre-assembled cabling

Degree of protection (IP), front side

IP65

Width

88mm

Degree of protection (NEMA)

12

Depth

188mm

Height

88mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.