
T5-4-15164/V/SVB
Code: 1042072

T5-4-15164/V/SVB

Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-23, 400 V
100A
Version as reversing switch
Version as maintenance-/service switch
Version as safety switch
Number of switches
1
Rated permanent current Iu
100A
Version as main switch
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Rated short-time withstand current lcw
1.7kA
Rated permanent current at AC-21, 400 V
100A
Switching power at 400 V
55kW
Rated operation power at AC-23, 400 V
55kW
Number of poles
6
Rated operation power at AC-3, 400 V
30kW
Number of auxiliary contacts as normally open contact
2
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Motor drive optional
Motor drive integrated
Conditioned rated short-circuit current Iq
2kA
Device construction
Built-in device fixed built-in technique
Suitable for front mounting centre
Suitable for intermediate mounting
Type of control element
Door coupling rotary drive
Suitable for front mounting 4-hole
Type of electrical connection of main circuit
Screw connection
Interlockable
With pre-assembled cabling
Degree of protection (NEMA)
12
Suitable for distribution board installation
Suitable for floor mounting
Width
88mm
Colour control element
Red
Height
88mm
Degree of protection (IP), front side
IP65
Depth
188mm