Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC690V
Rated permanent current at AC-23, 400 V100A
Version as reversing switchNo
Version as maintenance-/service switchYes
Version as safety switchNo
Number of switches1
Rated permanent current Iu100A
Version as main switchYes
Rated operating voltage690 - 690V
Version as emergency stop installationYes
Rated short-time withstand current lcw1.7kA
Rated permanent current at AC-21, 400 V100A
Switching power at 400 V55kW
Rated operation power at AC-23, 400 V55kW
Number of poles6
Rated operation power at AC-3, 400 V30kW
Number of auxiliary contacts as normally open contact2
Number of auxiliary contacts as normally closed contact1
Number of auxiliary contacts as change-over contact0
Voltage release optionalNo
Motor drive optionalNo
Motor drive integratedNo
Conditioned rated short-circuit current Iq2kA
Device constructionBuilt-in device fixed built-in technique
Suitable for front mounting centreNo
Suitable for intermediate mountingYes
Type of control elementDoor coupling rotary drive
Suitable for front mounting 4-holeNo
Type of electrical connection of main circuitScrew connection
InterlockableYes
With pre-assembled cablingNo
Degree of protection (NEMA)12
Suitable for distribution board installationNo
Suitable for floor mountingYes
Width88mm
Colour control elementRed
Height88mm
Degree of protection (IP), front sideIP65
Depth188mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

T5-4-15164/V/SVB

Main Product Image

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Max. rated operation voltage Ue AC

690V

Rated permanent current at AC-23, 400 V

100A

Version as reversing switch

Version as maintenance-/service switch

Version as safety switch

Number of switches

1

Rated permanent current Iu

100A

Version as main switch

Rated operating voltage

690 .. 690V

Version as emergency stop installation

Rated short-time withstand current lcw

1.7kA

Rated permanent current at AC-21, 400 V

100A

Switching power at 400 V

55kW

Rated operation power at AC-23, 400 V

55kW

Number of poles

6

Rated operation power at AC-3, 400 V

30kW

Number of auxiliary contacts as normally open contact

2

Number of auxiliary contacts as normally closed contact

1

Number of auxiliary contacts as change-over contact

0

Voltage release optional

Motor drive optional

Motor drive integrated

Conditioned rated short-circuit current Iq

2kA

Device construction

Built-in device fixed built-in technique

Suitable for front mounting centre

Suitable for intermediate mounting

Type of control element

Door coupling rotary drive

Suitable for front mounting 4-hole

Type of electrical connection of main circuit

Screw connection

Interlockable

With pre-assembled cabling

Degree of protection (NEMA)

12

Suitable for distribution board installation

Suitable for floor mounting

Width

88mm

Colour control element

Red

Height

88mm

Degree of protection (IP), front side

IP65

Depth

188mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.